Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.170
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38565427

RESUMO

Transcatheter heart valve (THV) procedures require careful planning and consideration to prevent coronary artery obstruction (CAO), which poses a significant and potentially life-threatening condition, especially in patients undergoing valve-in-valve (ViV) transcatheter aortic valve replacement (TAVR). Despite identifying predictors of CAO and utilization of computed tomography and inputting THV features, a significant uncertainty remains in predicting CAO. The ShortCut™ device (Pi-Cardia, Rehovot, Israel) was purposefully designed to modify the leaflets in patients undergoing TAVR, especially prior to ViV procedures, to overcome the risk for CAO. This review aims to detail the device's objectives, structure, procedural steps, the available clinical data, and future directions for its intended utilization in the structural arena for the prevention of CAO.

2.
Artigo em Inglês | MEDLINE | ID: mdl-38637194

RESUMO

BACKGROUND: Coronary functional testing to formally diagnose coronary microvascular dysfunction (CMD) reduces cardiovascular events and alleviates angina. This study aims to investigate the extensive and complex journey that patients with CMD undergo, from the onset of chest pain to eventual diagnosis. METHODS: Data from the Coronary Microvascular Disease Registry (CMDR) were analyzed, including information on the date of first documentation of chest pain, number of non-invasive and invasive tests the patient underwent, emergency department visits, and hospitalizations. In addition, we estimated the total cost per patient. A total of 61 patients with CMD diagnosis were included in this analysis. RESULTS: Most patients in our cohort were older than 50 years of age. The median time from initial chest pain symptoms to diagnosis was 0.62 (interquartile range [IQR]: 0.06-2.96) years. During this period, patients visited the emergency department a median of 1.0 (IQR: 0.0-2.0) times. Diagnostic tests included 3.0 (IQR: 2.0-6.0) electrocardiograms, 3.0 (IQR: 0.0-6.0) high-sensitivity troponin tests, and 1.0 (IQR: 1.0-2.0) echocardiograms. Prior to diagnosis of CMD, 13 (21.3 %) patients had left heart catheterization without coronary functional testing. Non-invasive testing for ischemia was conducted in 43 (70.5 %) patients. Alternative non-cardiac diagnoses were given to 11 (18.0 %) patients during the diagnostic process, with referrals made to gastroenterology for 16 (26.2 %) and pulmonology for 10 (16.4 %) patients. The cost was almost $2000/patient. CONCLUSION: Timely identification of CMD offers promising opportunities for prompt symptom alleviation, accompanied by reduced visits to the emergency department, cardiovascular testing, invasive medical procedures, and consequently reduced healthcare expenses.

4.
Artigo em Inglês | MEDLINE | ID: mdl-38605682

RESUMO

The advent of excimer laser coronary atherectomy (ELCA) nearly four decades ago heralded a novel way to treat complex lesions, both coronary and peripheral, which were previously untraversable and thus untreatable. These complex lesions include heavily calcified lesions, ostial lesions, bifurcation lesions, chronic total occlusions, in-stent restenosis (including stent underexpansion), and degenerative saphenous vein grafts. We discuss the technology of ELCA, its indications, applications, and complications, and suggest the "MAXCon ELCA" technique for better outcomes without increased risk. Lastly, we present a case of MAXCon ELCA effectively treating a complex lesion.

5.
Artigo em Inglês | MEDLINE | ID: mdl-38631936

RESUMO

BACKGROUND: Coronary microvascular dysfunction (CMD) is a prevalent condition among patients with cardiovascular risk factors, leading to a reduced quality of life and an increased risk of major adverse cardiovascular events. Novel invasive techniques have emerged to more accurately diagnose CMD. However, CMD's natural history remains poorly understood due to limited data. To address this knowledge gap, the Coronary Microvascular Disease Registry (CMDR) was established with the primary aim of standardizing comprehensive coronary functional testing and understanding of CMD. DESIGN: CMDR is a prospective, multicenter registry enrolling an unlimited number of consecutive subjects who undergo comprehensive invasive hemodynamic assessment of the entire coronary arterial vasculature. Patients undergoing acetylcholine provocation test for coronary vasospasm will also be included. Follow-up assessments will be conducted at 30 days and annually for up to 5 years. The primary endpoint is Canadian Cardiovascular Society angina grade over time. Secondary endpoints, including all-cause mortality, cardiovascular death, acute myocardial infarction, stroke, hospitalizations, medication changes, and subsequent coronary interventions, will be analyzed to establish long-term safety and clinical outcomes in patients undergoing invasive CMD assessment. SUMMARY: CMDR aims to characterize the clinical and physiologic profile of patients undergoing comprehensive invasive coronary functional testing, simultaneously providing crucial longitudinal information on the natural history and outcomes of these patients. This will shed light on CMD's course and clinical implications, which, in turn, holds the potential to significantly improve diagnostic and treatment strategies for CMD patients, ultimately leading to the enhancement of their overall prognosis and quality of life. CLINICAL TRIAL REGISTRATION: clinicaltrials.gov, NCT05960474.

6.
Catheter Cardiovasc Interv ; 103(5): 703-709, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38520176

RESUMO

BACKGROUND: Full adoption of coronary microvascular dysfunction (CMD) assessment faces challenges due to its invasive nature and concerns about prolonged procedure time and increased contrast and/or radiation exposure. We compared procedural aspects of CMD invasive assessment to diagnostic left heart catheterization (DLHC) in patients with chest pain who were not found to have obstructive coronary artery disease. METHODS: A total of 227 patients in the Coronary Microvascular Disease Registry were compared to 1592 patients who underwent DLHC from August 2021 to November 2023. The two cohorts were compared using propensity-score matching; primary outcomes were fluoroscopy time and total contrast use. RESULTS: The participants' mean age was 64.1 ± 12.6 years. CMD-assessed patients were more likely to be female (66.5% vs. 45.2%, p < 0.001) and have hypertension (80.2% vs. 44.5%, p < 0.001), history of stroke (11.9% vs. 6.3%, p = 0.002), and history of myocardial infarction (20.3% vs. 7.7%, p < 0.001). CMD assessment was safe, without any reported adverse outcomes. A propensity-matched analysis showed that patients who underwent CMD assessment had slightly higher median contrast exposure (50 vs. 40 mL, p < 0.001), and slightly longer fluoroscopy time (6.9 vs. 4.7 min, p < 0.001). However, there was no difference in radiation dose (209.3 vs. 219 mGy, p = 0.58) and overall procedure time (31 vs. 29 min, p = 0.37). CONCLUSION: Compared to DLHC, CMD assessment is safe and requires only slightly additional contrast use (10 mL) and slightly longer fluoroscopy time (2 min) without clinical implications. These findings emphasize the favorable safety and feasibility of invasive CMD assessment.


Assuntos
Doença da Artéria Coronariana , Angina Microvascular , Infarto do Miocárdio , Isquemia Miocárdica , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Masculino , Resultado do Tratamento , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Angina Microvascular/diagnóstico , Circulação Coronária , Microcirculação , Vasos Coronários/diagnóstico por imagem
7.
Catheter Cardiovasc Interv ; 103(5): 691-694, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38440925

RESUMO

BACKGROUND: With advances in technology and technique, the expectations are that patients undergoing procedures in the cardiac catheterization laboratory will not need to return for a repeat procedure within the same day. OBJECTIVES: Report why subjects undergoing cardiac procedures return urgently to the catheterization laboratory for a repeat procedure during the same day. METHODS: We retrospectively reviewed patients who were brought back to the cardiac catheterization laboratory within the same day for a repeat procedure. The reasons for index and repeat procedure were identified. Patients who were transferred from an outside center after an initial procedure at other centers were excluded. RESULTS: Between November 2013 and January 2022, 55,942 catheterization procedures were performed at our institution, of which 140 entries were included in our analysis. Common reasons for the index procedure were diagnostic angiography (35.0%), percutaneous coronary intervention (PCI, 29.2%), and transcatheter aortic valve replacement (15.0%). The most common reason for bringing these patients back to the cardiac catheterization laboratory within the same day was vascular complications (24.2%), followed by repeat PCI (20.7%), need for hemodynamic support (15.0%), heart team discussion and PCI (10%), and pacemaker implantation (10%). Acute limb ischemia was the most commonly identified vascular complication (7.1%), followed by pseudoaneurysm (5%). CONCLUSION: Our study demonstrates that a very small number of patients underwent repeat procedures within the same day. Special attention should be paid to vascular access and closure and assessment of recurrent chest pain postprocedure, as these are the main reasons for same-day repeat procedures.


Assuntos
Estenose da Valva Aórtica , Marca-Passo Artificial , Intervenção Coronária Percutânea , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/métodos , Estudos Retrospectivos , Resultado do Tratamento , Angiografia , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/métodos
8.
Catheter Cardiovasc Interv ; 103(4): 523-531, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38440914

RESUMO

BACKGROUND: Percutaneous coronary intervention (PCI) is considered less safe in patients with reduced ejection fraction (EF), an impression based on older data. Whether the safety and durability of contemporary PCI are different in patients with reduced EF compared with normal EF patients is unknown. METHODS: Patients from the BIOFLOW II, IV and V clinical trials were grouped as normal EF (≥50%) and reduced EF (30%-50%). Using multivariable logistic regression and cox proportional hazards regression, we determined relations of EF category with procedural safety (a composite of cardiac death, myocardial infarction, stroke and urgent coronary artery bypass grafting within 30 days of PCI) and target lesion failure (TLF; comprising cardiac death, target vessel myocardial infarction, target vessel revascularization within 1 year of PCI) respectively. In sensitivity analyses, we regrouped patients into EF < 45% and ≥55% and repeated the aforementioned analyses. RESULTS: In 1685 patients with normal EF (mean age 65 years; 27% women; mean EF 61%) and 259 with low EF (mean age 64 years; 17% women; mean EF 41%), 101 safety and 148 TLF events occurred. Compared with patients in the normal EF group, those with reduced EF had neither a statistically significant higher proportion of safety events, nor a higher multivariable-adjusted risk for such events. Similarly, patients with reduced EF and normal EF did not differ in terms of TLF event proportions or multivariable-adjusted risk for TLF. The results were similar in sensitivity analyses with EF groups redefined to create a 10% between-group EF separation. CONCLUSION: PCI safety and durability outcomes are similar in patients with mild-moderately reduced EF and normal EF.


Assuntos
Infarto do Miocárdio , Intervenção Coronária Percutânea , Disfunção Ventricular Esquerda , Humanos , Feminino , Idoso , Pessoa de Meia-Idade , Masculino , Intervenção Coronária Percutânea/efeitos adversos , Resultado do Tratamento , Infarto do Miocárdio/etiologia , Ponte de Artéria Coronária/efeitos adversos , Disfunção Ventricular Esquerda/etiologia , Morte
9.
Am Heart J ; 271: 112-122, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38395293

RESUMO

BACKGROUND: To date, there has been no independent core lab angiographic analysis of patients with COVID-19 and STEMI. The study characterized the angiographic parameters of patients with COVID-19 and STEMI. METHODS: Angiograms of patients with COVID-19 and STEMI from the North American COVID-19 Myocardial Infarction (NACMI) Registry were sent to a Core Laboratory in Vancouver, Canada. Culprit lesion(s), Thrombolysis In Myocardial Infarction (TIMI) flow, Thrombus Grade Burden (TGB), and percutaneous coronary intervention (PCI) outcome were assessed. RESULTS: From 234 patients, 74% had one culprit lesion, 14% had multiple culprits and 12% had no culprit identified. Multivessel thrombotic disease and multivessel CAD were found in 27% and 53% of patients, respectively. Stent thrombosis accounted for 12% of the presentations and occurred in 55% of patients with previous coronary stents. Of the 182 who underwent PCI, 60 (33%) had unsuccessful PCI due to post-PCI TIMI flow <3 (43/60), residual high thrombus burden (41/60) and/or thrombus related complications (27/60). In-hospital mortality for successful, partially successful, and unsuccessful PCI was 14%, 13%, and 27%, respectively. Unsuccessful PCI was associated with increased risk of in-hospital mortality (risk ratio [RR] 1.96; 95% CI: 1.05-3.66, P = .03); in the adjusted model this estimate was attenuated (RR: 1.24; 95% CI: 0.65-2.34, P = .51). CONCLUSION: In patients with COVID-19 and STEMI, thrombus burden was pervasive with notable rates of multivessel thrombotic disease and stent thrombosis. Post-PCI, persistent thrombus and sub-optimal TIMI 3 flow rates led to one-third of the PCI's being unsuccessful, which decreased over time but remained an important predictor of in-hospital mortality.


Assuntos
COVID-19 , Angiografia Coronária , Intervenção Coronária Percutânea , Sistema de Registros , Infarto do Miocárdio com Supradesnível do Segmento ST , Humanos , Infarto do Miocárdio com Supradesnível do Segmento ST/terapia , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico por imagem , COVID-19/complicações , COVID-19/terapia , Masculino , Feminino , Intervenção Coronária Percutânea/métodos , Intervenção Coronária Percutânea/estatística & dados numéricos , Pessoa de Meia-Idade , Idoso , Mortalidade Hospitalar , SARS-CoV-2 , Trombose Coronária/diagnóstico por imagem , Canadá/epidemiologia
10.
EuroIntervention ; 20(1): 32-44, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38165117

RESUMO

Atherosclerosis is a chronic condition characterised by the build-up of plaque in the inner lining of the blood vessels and it is the main underlying cause of cardiovascular disease. The development of atherosclerosis is associated with the accumulation of cholesterol and inflammation. Although effective therapies exist to lower low-density lipoprotein cholesterol (LDL-C) levels, some patients still experience cardiovascular events due to persistent inflammation, known as residual inflammatory risk (RIR). Researchers have conducted laboratory and animal studies to investigate the measurement and targeting of the inflammatory cascade associated with atherosclerosis, which have yielded promising results. In addition to guideline-directed lifestyle modifications and optimal medical therapy focusing on reducing LDL-C levels, pharmacological interventions targeting inflammation may provide further assistance in preventing future cardiac events. This review aims to explain the mechanisms of inflammation in atherosclerosis, identifies potential biomarkers, discusses available therapeutic options and their strengths and limitations, highlights future advancements, and summarises notable clinical studies. Finally, an evaluation and management algorithm for addressing RIR is presented.


Assuntos
Aterosclerose , Doenças Cardiovasculares , Animais , Humanos , LDL-Colesterol , Inflamação , Doenças Cardiovasculares/prevenção & controle , Colesterol , Fatores de Risco
11.
EuroIntervention ; 20(2): e146-e157, 2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-38224255

RESUMO

BACKGROUND: There are limited data on the impact of transcatheter heart valve (THV) type on the outcomes of surgical explantation after THV failure. AIMS: We sought to determine the outcomes of transcatheter aortic valve replacement (TAVR) explantation for failed balloon-expandable valves (BEV) versus self-expanding valves (SEV). METHODS: From November 2009 to February 2022, 401 patients across 42 centres in the EXPLANT-TAVR registry underwent TAVR explantation during a separate admission from the initial TAVR. Mechanically expandable valves (N=10, 2.5%) were excluded. The outcomes of TAVR explantation were compared for 202 (51.7%) failed BEV and 189 (48.3%) failed SEV. RESULTS: Among 391 patients analysed (mean age: 73.0±9.8 years; 33.8% female), the median time from index TAVR to TAVR explantation was 13.3 months (interquartile range 5.1-34.8), with no differences between groups. Indications for TAVR explantation included endocarditis (36.0% failed SEV vs 55.4% failed BEV; p<0.001), paravalvular leak (21.2% vs 11.9%; p=0.014), structural valve deterioration (30.2% vs 21.8%; p=0.065) and prosthesis-patient mismatch (8.5% vs 10.4%; p=0.61). The SEV group trended fewer urgent/emergency surgeries (52.0% vs 62.3%; p=0.057) and more root replacement (15.3% vs 7.4%; p=0.016). Concomitant cardiac procedures were performed in 57.8% of patients, including coronary artery bypass graft (24.8%), and mitral (38.9%) and tricuspid (14.6%) valve surgery, with no differences between groups. In-hospital, 30-day, and 1-year mortality and stroke rates were similar between groups (allp>0.05), with no differences in cumulative mortality at 3 years (log-rank p=0.95). On multivariable analysis, concomitant mitral surgery was an independent predictor of 1-year mortality after BEV explant (hazard ratio [HR] 2.00, 95% confidence interval [CI]: 1.07-3.72) and SEV explant (HR 2.00, 95% CI: 1.08-3.69). CONCLUSIONS: In the EXPLANT-TAVR global registry, BEV and SEV groups had different indications for surgical explantation, with more root replacements in SEV failure, but no differences in midterm mortality and morbidities. Further refinement of TAVR explantation techniques are important to improving outcomes.


Assuntos
Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Masculino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Remoção de Dispositivo , Cateteres , Valvas Cardíacas , Sistema de Registros
13.
Cardiovasc Revasc Med ; 58: 45-49, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37393190

RESUMO

PURPOSE: Explore gender disparities in patients undergoing transseptal puncture (TSP) for selected transcatheter cardiac intervention procedures. METHODS: Patients who underwent TSP from January 2015 through September 2021 were reviewed. Primary outcomes were procedural and in-hospital major adverse events. Secondary endpoints were procedural success and hospitalization length of stay (LOS) >1 day. Unadjusted and multivariable-adjusted logistic regression analyses were performed to assess gender differences for in-hospital adverse events. RESULTS: The study cohort comprised 510 patients (mean [SD] age, 74 [14.0] years); 246 women (48 %) underwent TSP for left atrial appendage occlusion (LAAO) or transcatheter edge-to-edge-repair (TEER). Compared with men, women were younger, had higher CHA2DS2-VASc scores, and were more likely to have had a prior ischemic stroke, but were less likely to have paroxysmal atrial fibrillation. After multivariable adjustment, there were no differences between genders in aborted or canceled procedures (odds ratio [OR]: 0.43; 95 % confidence interval [CI]: 0.10-1.96; p = 0.277), any adverse events (OR: 1.00; 95 % CI: 0.58-1.70; p = 0.98), major adverse events (OR: 1.60; 95 % CI: 0.90-2.80; p = 0.11), or death (OR: 1.00; 95 % CI: 0.20-5.00; p = 0.31). Subgroup analysis for LAAO procedures showed that at 30 days, women had higher rates of adverse events, major adverse cardiac events, and LOS >1 day. CONCLUSIONS: Men and women showed no differences in procedural success and in-hospital adverse outcomes in unadjusted analysis and after multivariable adjustment, despite women having a higher risk profile among patients undergoing TSP. However, compared with men, women undergoing LAAO experienced a higher rate of in-hospital adverse events irrespective of TSP.


Assuntos
Apêndice Atrial , Fibrilação Atrial , AVC Isquêmico , Acidente Vascular Cerebral , Humanos , Masculino , Feminino , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia , Fibrilação Atrial/complicações , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/métodos , AVC Isquêmico/etiologia , Fatores de Tempo , Resultado do Tratamento , Acidente Vascular Cerebral/etiologia
15.
Cardiovasc Revasc Med ; 59: 76-80, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37689575

RESUMO

BACKGROUND: Computed tomography with fractional flow reserve (CT-FFR) is increasingly common in assessing coronary artery disease. CASE PRESENTATION: We report five cases of discrepancies that led to changes in treatment. CONCLUSIONS: This report highlights discordant findings between modalities, which should be considered during the diagnostic assessment of chest pain.


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Humanos , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/terapia , Angiografia Coronária/métodos , Sensibilidade e Especificidade , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Tomografia Computadorizada por Raios X/métodos , Angiografia por Tomografia Computadorizada/métodos , Valor Preditivo dos Testes , Estudos Retrospectivos
16.
Cardiovasc Revasc Med ; 59: 9-13, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37550124

RESUMO

BACKGROUND/PURPOSE: The cusp overlap technique has standardized implantation for self-expanding valves with the goal of achieving more consistent implantation depths and lowering permanent pacemaker (PPM) implantation rates. We retrospectively compared short-term outcomes in patients undergoing transcatheter aortic valve replacement (TAVR) with a self-expanding valve implanted using the cusp overlap technique vs. the traditional coplanar technique in a large tertiary referral center. METHODS: We conducted a retrospective study among PPM-naïve patients who underwent TAVR using the CoreValve Evolut PRO/PRO+. We compared in-hospital PPM rates in patients who underwent TAVR using the cusp overlap technique vs. the coplanar technique. Additional outcomes included in-hospital all-cause mortality, stroke, major vascular complications, annular rupture, and >mild paravalvular leak. Furthermore, we compared outcomes over time to see whether there was evidence of a learning curve. RESULTS: Of the 528 patients included, 270 underwent TAVR using the coplanar technique and 258 underwent TAVR using the cusp overlap technique. The rate of new PPM implantation did not differ between cohorts (17.0 % vs. 16.7 %; p = 0.910). Additionally, rates of in-hospital all-cause mortality (0.0 % vs. 0.4 %; p = 0.328), stroke (3.7 % vs. 1.6 %; p = 0.124), major vascular complications (0.7 % vs. 1.2 %; p = 0.617), annular rupture (0.4 % vs. 0.0 %; p = 0.328) and >mild paravalvular leak (0.0 % vs. 0.4 %; p = 0.444) were similar. Our secondary analysis did not identify any evidence of a learning curve. CONCLUSIONS: The cusp overlap technique may not yield a reduction in PPM rates when compared with the coplanar technique. Other confounders should be explored to further minimize in-hospital PPM rates.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Marca-Passo Artificial , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estudos Retrospectivos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Fatores de Risco , Desenho de Prótese
17.
Am Heart J ; 269: 108-117, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38128897

RESUMO

Hypertension remains a leading preventable cause of myocardial infarction, stroke, kidney disease, and cardiovascular death worldwide. Despite lifestyle modifications and intensification of medical therapy, suboptimal blood pressure control is common, spurring the development of device-based therapies for hypertension. The US Food and Drug Administration (FDA) assembled the Circulatory System Devices Panel on August 22-23, 2023, to discuss the safety and effectiveness of renal denervation devices manufactured by Recor Medical and Medtronic. After reviewing the ultrasound-based Recor Paradise renal denervation system the day prior, the panel reconvened to discuss the radiofrequency-based Medtronic Symplicity Spyral Renal Denervation System. In this manuscript, we summarize the data presented by the sponsor and FDA and detail the deliberation and discussion during the meeting.


Assuntos
Sistema Cardiovascular , Hipertensão , Estados Unidos , Humanos , United States Food and Drug Administration , Rim/cirurgia , Pressão Sanguínea , Simpatectomia , Resultado do Tratamento , Anti-Hipertensivos/uso terapêutico
18.
Cardiovasc Revasc Med ; 59: 1-2, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38123428
19.
Int J Cardiol ; 395: 131431, 2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-37832606

RESUMO

BACKGROUND: Recent randomized studies have broadened the indication of transcatheter aortic valve replacement (TAVR) to also include low-surgical-risk patients. However, the data on self-expanding (SE) and balloon-expandable (BE) valves in low-risk patients remain sparse. METHODS: The current study is a post hoc analysis of combined data from both LRT 1.0 and 2.0 trials comparing BE and SE transcatheter heart valves. RESULTS: A total of 294 patients received a BE valve, and 102 patients received an SE valve. The 30-day clinical outcomes were similar across both groups except for stroke (4.9% vs. 0.7%, p = 0.014) and permanent pacemaker implantation (17.8% vs. 5.8%, p < 0.001), which were higher in the SE cohort than the BE cohort. No difference was observed in terms of paravalvular leak (≥moderate) between the groups (0% vs. 1.5%, p = 0.577). SE patients had higher aortic valve area (1.92 ± 0.43 mm2 vs. 1.69 ± 0.45 mm2, p < 0.001) and lower mean gradient (8.93 ± 3.53 mmHg vs. 13.41 ± 4.73 mmHg, p < 0.001) than BE patients. In addition, the rate of subclinical leaflet thrombosis was significantly lower in SE patients (5.6% vs. 13.8%, p = 0.038). CONCLUSION: In this non-randomized study assessing SE and BE valves in low-risk TAVR patients, SE valves are associated with better hemodynamics and lesser leaflet thrombosis, with increased rates of stroke and permanent pacemaker implantation at 30 days; however, this could be due to certain patient-dependent factors not fully evaluated in this study. The long-term implications of these outcomes on structural valve durability remain to be further investigated. CLINICAL TRIAL REGISTRY: LRT 1.0: NCT02628899 LRT 2.0: NCT03557242.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Acidente Vascular Cerebral , Trombose , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia , Acidente Vascular Cerebral/etiologia , Trombose/etiologia , Resultado do Tratamento , Desenho de Prótese , Fatores de Risco
20.
Am J Cardiol ; 214: 1-7, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38110018

RESUMO

Transcatheter aortic valve replacement (TAVR) provides an option for extreme-risk patients who underwent reoperation for a failed surgical aortic bioprosthesis. Long-term data on patients who underwent TAVR within a failed surgical aortic valve (TAV-in-SAV) are limited. The CoreValve Expanded Use Study evaluated patients at extreme surgical risk who underwent TAV-in-SAV. Outcomes at 5 years were analyzed by SAV failure mode (stenosis, regurgitation, or combined). Echocardiographic outcomes are site-reported. TAV-in-SAV was attempted in 226 patients with a mean age of 76.7 ± 10.8 years; 63.3% were male, the Society of Thoracic Surgeons predicted risk of mortality score was 9.0 ± 6.7%, and 87.5% had a New York Heart Association classification III or IV symptoms. Most of the failed surgical bioprostheses were stented (81.9%), with an average implant duration of 10.2 ± 4.3 years. The 5-year all-cause mortality or major stroke rate was 47.2% in all patients; 54.4% in the stenosis, 37.6% in the regurgitation, and 38.0% in the combined groups (p = 0.046). At 5 years, all-cause mortality was higher in patients with versus without 30-day severe prosthesis-patient mismatch (51.7% vs 38.3%, p = 0.026). The overall aortic valve reintervention rate was 5.9%; highest in the regurgitation group (12.6%). The mean aortic valve gradient was 14.1 ± 9.8 mm Hg and effective orifice area was 1.57 ± 0.70 at 5 years. Few patients had >mild paravalvular regurgitation at 5 years (5.5% moderate, 0.0% severe). TAV-in-SAV with supra-annular, self-expanding TAVR continues to represent a safe and lasting intermediate option for extreme-risk patients who have appropriate sizing of the preexisting failed surgical valve. Clinical and hemodynamic outcomes were stable through 5 years.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Idoso , Idoso de 80 Anos ou mais , Feminino , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Seguimentos , Constrição Patológica/etiologia , Constrição Patológica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia , Resultado do Tratamento , Substituição da Valva Aórtica Transcateter/efeitos adversos , Instrumentos Cirúrgicos , Desenho de Prótese , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...